No. I-11015/3/2022-ICT Date: 27-07-2026 To, 1. Zonal Insurance Commissioner(s)/Zonal Medical Commissioner(s) 2. Regional Directors/Directors (I/c)/Joint Directors (I/c) of all ROs/SROs 3. Medical Superintendent(s) of all ESIC Medical Hospitals 4. Dean(s) of all ESIC Medical Colleges and Hospitals 5. Director (Medical),…
Official record
Open source pageSource details
- Source
- Employees' State Insurance Corporation
- Type
- circular
- Published by source
- 20 Aug 2025
- Coverage area
- labour
Document text
No. I-11015/3/2022-ICT Date: 27-07-2026 To,
- Zonal Insurance Commissioner(s)/Zonal Medical Commissioner(s)
- Regional Directors/Directors (I/c)/Joint Directors (I/c) of all ROs/SROs
- Medical Superintendent(s) of all ESIC Medical Hospitals
- Dean(s) of all ESIC Medical Colleges and Hospitals
- Director (Medical), Delhi
- Director (Medical), Noida
- Director, National Training Academy (NTA)
Subject: Standard Specifications for LAN Cabling and Associated Networking Components
Reference: Headquarters letter No. E-323/I-11013/4/2021-ICT dated 21.08.2025 regarding the Policy for Procurement of IT Hardware for ESI Locations.
Madam/Sir,
With reference to the Headquarters letter cited above, the standard Bill of Quantities (BoQ) and minimum technical specifications for LAN cabling and associated networking components are enclosed as Annexure-I for adoption by all ESIC field units while undertaking procurement of structured cabling and related networking infrastructure.
-
All field units shall adhere to the specifications prescribed in Annexure-I while procuring LAN cabling, optical fibre cabling, racks, passive networking components, and other associated items covered therein.
-
Any deviation from the prescribed specifications, if necessitated by site-specific or technical requirements, shall require the prior approval of the ICT Division, Headquarters. Such proposals shall be accompanied by a detailed technical justification and comparative specifications for examination.
I-11015/3/2022-ICT I/4171999/2026
-
Field units where procurement has already been initiated prior to the issuance of this circular may continue with the ongoing procurement process without any modification.
-
All other terms and conditions contained in Headquarters letter No. E-323/I-11013/4/2021-ICT dated 21.08.2025 shall remain unchanged.
This issues with the approval of the Competent Authority.
Yours faithfully,
(Himanshu Antil) Deputy Director (ICT)
I-11015/3/2022-ICT I/4171999/2026
Annexure-I Standard BoQ for LAN Cabling and Associated Networking Components
| Sl. No. | Item Description |
|---|---|
| 1 | CAT-6 UTP Cable, @305 m Roll, 100% Bare Copper Conductor |
| 2 | 24-Port CAT-6 Patch Panel |
| 3 | 9U, 19-inch Network/Server Rack Enclosure |
| 4 | 12U, 19-inch Network/Server Rack Enclosure |
| 5 | Information Outlet (I/O) comprising Face Plate, Box and CAT-6 Keystone Jack |
| 6 | Factory-Terminated CAT-6 Patch Cord – 1 m |
| 7 | Factory-Terminated CAT-6 Patch Cord – 2 m |
| 8 | Factory-Terminated CAT-6 Patch Cord – 3 m |
| 9 | 6-Core Single Mode Armoured Optical Fibre Cable (OFC) ncluding ISI-marked PVC Conduit and Accessories– per metre |
| 10 | Single Mode OFC Patch Cord – 2 m |
| 11 | 12-Port Optical Fibre Light Interface Unit (LIU) complete with Couplers |
| 12 | Optical Fibre Splicing Charges – per Core |
| 13 | Optical Fibre Cable Laying Charges – per metre |
| 14 | RJ-45 Connector/Termination including Installation Charges |
| 15 | CAT-6 Cable Laying including ISI-marked PVC Conduit and Accessories – per metre |
| 16 | Floor Cutting and Restoration/Finishing – per metre |
| 17 | Dressing and Cable Management of Rack |
| 18 | 5-Port Surge-Protected Power Strip/Spike Guard with 4–5 m Copper Power Cord (10 A, 2500 W minimum) |
Note:
- The above items represent the standard BoQ for procurement of structured cabling components across ESIC field units.
- The detailed minimum technical specifications for each item shall be as prescribed by the ICT Division from time to time and shall form part of the tender documents.
- Equivalent or higher specifications may be adopted only with the prior approval of the ICT Division, Headquarters.
I-11015/3/2022-ICT I/4171999/2026
Research the source law
Find the provision behind this update.
No high-confidence provision match was found. Browse the law library, choose the affected provision and ask against the exact statutory text.
Browse source lawsRelated ESIC updates
- Completion of pending APARs for the Reporting Year 2024–25 through the SPARROW Portal – reg
- List of Homeopathic Medicines date 01-08-2026 in IG ESIC Hospital, Jhilmil, Delhi
- Implementation of New Insured Person (IP) Registration functionality in ERP – reg
- Request for Submission of Indent for Underutilized Ortho Implants
- Corrigendum - Deletion of Item no. 1787, 1440 and 2103 from Approved List under DG ESIC Central RAte Contract No. 158 &163-reg